80
Genie Distribution WNET Manual v3
© Tieline Research Pty. Ltd. 2020
11.
Select
Module Configuration
to adjust other settings specific to how you want POTS
modules to dial and answer, e.g. Maximum connection bit rate and dial tone settings etc.
12. When configuration is complete press the
RETURN
button to navigate back to the
Connect POTS
screen.
Important Note:
At this point you can navigate to
Save
on the
Connect POTS
screen
and press
to use the numeric
KEYPAD
to name the program. Then press
to save
the program.
13. Press the
CONNECT
button to make a connection. The
Wait Connecting
screen
appears during the connection process.
Note: To load a saved program and dial press the
HOME
button, navigate to
Programs
,
select the program you want to dial and press the
CONNECT
button to load the program and
dial.
14. To negotiate higher bit rates press
then
3
on the numeric
KEYPAD
; for lower bit rates
press
then
9
.
Important Note:
To load a saved program and dial press the
HOME
button,
navigate to
Programs
, select the program you want to dial and press the
CONNECT
button to load the program and dial.
See
for more details on monitoring the different POTS connection
states.
18.6
Monitoring POTS Connections
Monitoring POTS Calls when Dialing and Connecting
1. When dialing and connecting:
·
The
CONNECTED LED
on the front of the unit will flash green.
·
The
Cxns
section on the
Home
screen displays
Pending
while the call is connecting (prior
to streaming audio data).