273
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
6. Configure the transport settings for the connection, then click
Next
. Note: select
UDP/IP +RTP
for RFC compliant streaming.
Important Note:
·
The encode and decode direction is configured automatically for
Encode Only
(server
program) or
Decode Only
(client program). This setting is configured when you select
either
Multicast Server
or
Multicast Client
when you first create the program in the
wizard.
·
The TTL value you need to use is dependent upon your network infrastructure. Please
consult your network administrator if you are unsure about how to configure this setting.
·
Use firmware higher than 2.8.xx in the Bridge-IT, Genie and Merlin families of codecs to
enable auxiliary data.
7. Configure the multicast IP address and
Remote Audio Port
(the same multicast address and
port must be used for both the server and client programs), then specify which IP streaming
interface is used to dial this connection, e.g.
Primary
(port
ETH1
) or
Secondary
(port
ETH2
),
then click
Next
. Note: By default
Any
will select
ETH1
if it is available and
ETH2
if it is
unavailable.
8. Click the drop-down arrows on the right-hand side of each text box to select the
Encoding
,
Sample rate
,
Bit rate
or
Sample size
options. Click
Next