2. Select
Multicast Client
to configure a client codec program.
3. Use the
RETURN
button to delete any numbers already entered, then use the numeric
KEYPAD
to enter the multicast IP address you want to dial, using the
or
buttons to
enter the periods in the IP address. The same multicast address and audio port must be used for
both the server and client programs. Next, press the down
navigation button to select
Setup
and press
.
4. Press the down
navigation button
to select
Algorithm
and press
.
5. Use the navigation buttons to select an algorithm profile, or manually select algorithm settings,
then press
.
6. Click to configure the Jitter Buffer from either
Auto Jitter Adapt
or
Fixed Buffer Level
, then
and enter the
Jitter Depth
, which must be between 12ms and 5000ms depending on the
algorithm you select, then press
.
Important Notes:
Automatic or fixed jitter buffer settings can be adjusted on individual
client codecs as required. There is no jitter buffer setting on the server codec because it
never receives audio packets.
7. Select
Protocol
to select the audio protocol and adjust the
Local Audio Port
. Select
UDP/IP
+RTP
for RFC compliant IP streaming. Press
to save settings.