89
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
5. Use the navigation buttons to select an algorithm profile, or manually select algorithm settings,
then press
.
6. Navigate to and select
TTL
and enter the IP Time-To-Live value, then press
. The TTL value
you need to use is dependent upon your network infrastructure. Please consult your network
administrator if you are unsure about how to configure this setting.
7. Select
Protocol
to select the audio protocol and adjust the
Remote Audio Port
. Select
UDP/IP +RTP
for RFC compliant IP streaming. Press
to save settings.
8. If required, enable
Auto Reconnect
and navigate to
Via
to specify which IP streaming interface
is used to dial this connection, e.g.
Primary
(port
ETH1
) or
Secondary
(port
ETH2
). Note: By
default
Any
will select
ETH1
if it is available and
ETH2
if it is unavailable.
9. Press the
RETURN
button when configuration is complete to navigate backwards to the
Connect IP
screen that the multicast IP address was entered into.
Important Note:
At this point you can navigate to
Save
on the
Connect IP
screen and
press
to save the settings as a custom program for subsequent recall and dialing. Use
the numeric
KEYPAD
to give the program a name and press
to save the program. A
confirmation message is displayed after the program is saved.