209
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
value for the
Local Audio Port
is
Automatic
. Note:
Automatic
indicates that
the codec will arbitrarily allocate the local port value and send this information
to the codec to which you are dialing. Click to deselect the
Automatic
check-
box and change this setting. When you select
Sessionless
as the
Session
Protocol
, the
Session Port
is not configurable and you can manually
configure the
Remote Audio Port
and
Local Audio Port
.
Click
Next Stream
to save default algorithm, jitter and FEC settings which are physically
entered in the codec. Alternatively, click
Next
to specify individual algorithm, jitter buffer
and FEC settings and configure a failover connection or SmartStream PLUS for this audio
stream (recommended).
Note:
Session Port 9002
and
Remote Audio Port 9000
are used by default for the first
IP audio stream. The audio for this audio steam will use analog or digital inputs and
outputs 1 and 2 for both the dialing and answering codecs. If you need to change default
port settings on the codec from which the call originates, this will also need to be
adjusted in the answering codec.
Click the drop-down arrows on the right-hand side of each text box to adjust the
Encoding
,
Sample rate
or
Bit rate
options.
Click to configure:
·
Auto Jitter Adapt
and the preferred auto jitter setting using the drop-down arrow for
Buffer priority
. It is also possible to configure the
Minimum depth
and
Maximum
depth
of jitter over the connection. See
·
Alternatively, select a
Fixed Buffer Level
and enter the
Jitter Depth
, which must
be between 12ms and 5000ms depending on the algorithm you select.
·
Local
and
Remote FEC
settings if required.
Important Notes:
·
If you select
Sessionless
or
SIP
as the
Session Protocol
then RFC-compliant FEC is
displayed. Configuration instructions are displayed in the right-hand pane.