148
Genie Distribution WNET Manual v3
© Tieline Research Pty. Ltd. 2020
iii.
Discrete recurring:
Uses the first interface that is not being used by another
connection (within the same audio stream). After all interfaces have been used,
each audio stream will scan each interface from the start again, in the order in
which they are listed, and connect using the first available interface that will
successfully dial and connect. The dialing order of the interfaces in the TieLink
panel can be adjusted by clicking a dragging interfaces on the left side of the
panel when it is in
Edit
mode.
iv.
Fuse-IP
: Connect using Fuse-IP data bonding. Multiple interfaces can be selected
and bonded to aggregate data and create a higher bandwidth connection. This is
configured in the
TieLink panel
as displayed in the following example. Please
note that this is the simplest way to configure a Fuse-IP connection.
Important Note:
Ensure an answering program is configured for Fuse-IP on the
destination codec and locked. Also ensure TieLink and relevant interfaces are enabled on
both codecs.
Helpful Hints for Troubleshooting
If TieLink Does Not Connect:
1. Ensure TieLink and at least one relevant interface is enabled and 'stunned' on both
codecs; i.e. the
STUN Status
for the interface is
Connected
.