222
Genie Distribution WNET Manual v3
© Tieline Research Pty. Ltd. 2020
·
Auto Jitter Adapt
and the preferred auto jitter setting using the drop-down arrow for
Buffer priority
. It is also possible to configure the
Minimum depth
and
Maximum
depth
of jitter over the connection. See
·
Alternatively, select a
Fixed Buffer Level
and enter the
Jitter Depth
, which must
be between 12ms and 5000ms depending on the algorithm you select.
·
Local
and
Remote FEC
settings if required.
Important Notes:
·
If you select
Sessionless
or
SIP
as the
Session Protocol
then RFC-compliant FEC is
displayed. Configuration instructions are displayed in the right-hand pane.
·
FEC Delay
is only available when the
FEC
percentage is
100%
. This is designed to
delay the sending of FEC packets for a predetermined period after the primary audio
stream's packets are sent. This will increase the likelihood that the FEC packets will
take an alternate route to the primary stream's packets. This means that if primary
audio stream packets are not received at the remote codec, there is a good chance
that FEC packets taking an alternate route will be received and replace them. When a
FEC
percentage lower than
100%
is configured, FEC packets are automatically delayed
based on the ratio of primary packets to FEC packets sent at the selected setting.
Select
Add a SmartStream PLUS Connection
to configure redundant IP streaming.
Alternatively, click
Next
to configure
Auto Reconnect
or a backup connection, whereby
the alternative connection is dialed if the primary connection fails.
By default, primary IP streaming is via
ETH1
. To achieve the maximum level of
redundancy select
Secondary
to configure redundant streaming from the secondary IP
port
ETH2
. The redundant stream uses
Remote Audio Port 9001
by default and the
Local Audio Port
allocated is
Automatic
. Note:
Automatic
indicates that the codec will
arbitrarily allocate the local port value and send this information to the codec to which you
are dialing.