Introduction
30 SL8500: Systems Assurance Guide • July 2011
E24254-01
Whenever possible, use a dedicated private network for communication
between the host management software (ACSLS, HSC, or other software) and
the library.
If a shared network is required, these actions can help with the communication
between the host and the library.
1. Directly connect the library to a switch.
2. Place the library on its own subnet.
3. Use a managed switch that can:
•
Set priorities on ports to give the host and library higher priority.
•
Provide dedicated bandwidth between the host and the library.
•
Create a VLAN between the host and the library.
4. Use a virtual private network (VPN) to insulate host to library traffic.
Network Recommendations
A private network connection to an Ethernet hub or switch is recommended for
maximum throughput and minimum resource contention.
When implementing the Dual TCP/IP feature, it is strongly recommended that
you and the system administrator work closely together to define the
configuration.
The simplest topology (private network connections to a hub or switch) is often
the best solution. Simplification will:
•
Offer maximum throughput
•
Provide minimum resource contention
•
Lend itself to higher security for library communication
•
Supply the least expensive alternative
•
Provide quick identification of any problems within the network
These are only suggestions; however, the customer’s network and their
desired topology are ultimately the determining factors. For certain topologies,
a more complicated setup is required. Many will require consultation between
the system administrator and another level of services.
Summary of Contents for StorageTek StreamLine SL8500
Page 4: ...Summary of Changes iv SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 12: ...Contents xii SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 18: ...Tables xviii SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 76: ...Introduction 56 SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 97: ...E24254 01 Chapter 3 Site Survey Forms 77 Site Survey Forms Figure 21 Content Management Plan ...
Page 137: ...E24254 01 Chapter 4 Site Preparation 117 Site Preparation ...
Page 138: ...Site Preparation 118 SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 198: ...Electrical Conversions 176 SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 206: ...Comparisons 184 SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 233: ...E24254 01 Appendix H Partitioning 211 Partitioning Make copies as necessary ...
Page 240: ...Partitioning 218 SL8500 Systems Assurance Guide July 2011 E24254 01 ...
Page 251: ...E24254 01 Appendix J Work Sheets 229 Work Sheets Figure 73 Content Management Work Sheet ...
Page 276: ...Index 254 SL8500 Systems Assurance Guide June 2011 E24254 01 ...
Page 277: ......
Page 278: ...Oracle Corporation Worldwide Headquarters 500 Oracle Parkway Redwood Shores CA 94065 U S A ...