Installation Instructions
CC129A-7
3.1
CUTTING AND INSTALLING CC129A COUPLANT SHEETS
Orientation of the CC129-1A is not critical. Cut the sheet to achieve the best coverage
and use of material. The full size (9” x 36”) sheet may be difficult to apply. Cutting the
sheet to manageable pieces will not affect efficiency. DO NOT INSTALL TRANSDUC-
ERS ON SEAMS.
3.1.1 SIZING SHEETS FOR PIPES 6-INCHES AND UNDER
l
Cut the 36-inch sheet length in half. The 18-inch length will be applied along the axis
of the pipe.
l
Leave the sheet at the full 9-inch width for pipes over 3 inches in diameter. Cut width
as needed to avoid significant overlap on pipes under 3 inches in diameter.
l
Cut any additional sheets as required (see Table 1 for proper number of CC129-1A
layers).
3.1.2 SIZING SHEETS FOR PIPES OVER 6 INCHES
l
Use the full CC129-1A sheet dimensions. The 36-inch length will be applied along the
pipe axis.
l
Depending on the transducer size code multiple layers may be required. Refer to
Table 1 for the correct number of CC129-1A layers to apply.
3.1.3 APPLYING CC129A COUPLANT SHEET TO PIPE
l
Verify that the ambient and pipe temperature fall within the temperature limits speci-
fied below Table 1.
Note that operating and installation temperatures are not the same.
l
Determine the proper location of the transducers (refer to paragraph 1 above).
l
Thoroughly clean and degrease the selected pipe area with a suitable solvent (see
Cautions in para. 3.1.5).
Transducer
Size
B1H
B2H
B3H
C1H
C2H
D1H
D2H
D3H
D4H
Required
Layers
1
1
1
1
1
2
3
2
4
Final Thickness
(in)
0.027
0.027
0.027
0.027
0.027
0.054
0.081
0.054
0.108
Final Thickness
(mm)
0.69
0.69
0.69
0.69
0.69
1.37
2.06
1.37
2.74
Table 1. CC129 Damping Material Thickness for 1010 Clamp-On Gas Systems
Operating Temperature Range
Installation Temperature Range
-10 to 250ºF (-23 to 93ºC)
32 to 120ºF (0 to 50ºC)
CC129-1A
Kit P/N
CC129-1A-1
CC129-1A-1
CC129-1A-1
CC129-1A-1
CC129-1A-1
CC129-1A-2
CC129-1A-3
CC129-1A-2
CC129-1A-4
Summary of Contents for SITRANS FUH1010PVX
Page 2: ......
Page 6: ......
Page 14: ......
Page 28: ......
Page 130: ......
Page 186: ......
Page 187: ...Siemens Hardware ...
Page 188: ......
Page 189: ...Siemens Hardware ...
Page 190: ......
Page 191: ...Siemens Hardware ...
Page 192: ......
Page 193: ...Siemens Hardware ...
Page 194: ......
Page 195: ...Siemens Hardware ...
Page 196: ...1010N 5 7 INSTALLATION DRAWING ANALOG INPUT MODULE 21614 C ...
Page 201: ...1011HNS 8 TRANSDUCER PART NUMBER L H W SIZE C D SIZE A B 21614 C Siemens Hardware ...
Page 202: ......
Page 203: ...Siemens Hardware ...
Page 204: ......
Page 206: ......
Page 214: ......
Page 225: ...Siemens Hardware ...