3-17
1010BXFM-3
Section 3
1. Perform all the required menu steps up until the point where the flow computer issues
the number index and prompts you to press <ENT> to finish the transducer install rou-
tine.
Make a note of the number index displayed in the Pick/Install menu. Check to ensure that you
have a matched set of transducers. They both should have the same S/N number but marked
with either an “A” or “B” (e.g., 100A and 100B).
2. Temporarily position one of the frames on the pipe where you will be mounting it. Ensure
that this is a smooth area without any raised areas (seams, etc.) With a pencil or chalk,
mark a generous area around the frame (1/2” on either side and half again the length
front and back). Remove the assembly.
3. Prepare the area you marked by de-greasing surface, if needed, and removing any grit,
corrosion, rust, loose paint or surface irregularities with the abrasive material provided.
4. Put a mounting strap around the pipe and engage an end into adjusting screw (screw should
be pointing up). Position frame in the middle of area you have cleaned and cen-
tered on the pipe with its angled end facing away from where the other frame will sit.
WRAPPING STRAP UNDER PIPE AND ATTACHING TO ADJUSTING SCREW
5. Slide the mounting strap over it (and under the clip if there is one) and tighten with a
screwdriver. While tightening, check to ensure that the center of the tapered roller is
centered on the pipe.
6. Attach the second frame to the spacer bar with an index spacer screw into the index hole
specified in Step 1. The angle on the frame should be facing away from the direction the
length of the bar is going. Now attach the free end of the spacer bar by inserting an index
spacer screw through the REF hole on the spacer bar and then into the hole on the mounted
frame. Tighten. Sight to ensure that this frame is lined up in center of pipe and while
holding alignment, place a dot (with pencil or chalk) in the center of the tapered roller at
MYLAR™ SPACING GUIDE
Mounting Strap
Adjusting Screw
Transducer
Clamping
Screw
Mounting Strap
Spring Clip
Summary of Contents for SITRANS FUH1010PVX
Page 2: ......
Page 6: ......
Page 14: ......
Page 28: ......
Page 130: ......
Page 186: ......
Page 187: ...Siemens Hardware ...
Page 188: ......
Page 189: ...Siemens Hardware ...
Page 190: ......
Page 191: ...Siemens Hardware ...
Page 192: ......
Page 193: ...Siemens Hardware ...
Page 194: ......
Page 195: ...Siemens Hardware ...
Page 196: ...1010N 5 7 INSTALLATION DRAWING ANALOG INPUT MODULE 21614 C ...
Page 201: ...1011HNS 8 TRANSDUCER PART NUMBER L H W SIZE C D SIZE A B 21614 C Siemens Hardware ...
Page 202: ......
Page 203: ...Siemens Hardware ...
Page 204: ......
Page 206: ......
Page 214: ......
Page 225: ...Siemens Hardware ...