Do not mount transducers from different ultrasonic flowmeters on the same pipe. Also, do
not run the transducer cables in common bundles with cables from communication equip-
ment, other Controlotron systems, or any type of ultrasonic equipment. You can run these
cables through a common conduit ONLY if they originate at the same flowmeter.
Never mount transducers under water, unless you order submersible units and you install
them in accordance with factory instructions.
Never mount transducers on the top or bottom of a horizontal pipe. The best placement on a
horizontal pipe is either the nine o’clock or three o’clock position for Reflect Mode, or one
transducer at nine o’clock and one transducer at three o’clock for Direct Mode. Mounting on
a vertical pipe is recommended only if flow is in the upward direction. When mounting on a
vertical pipe flowing in a downward direction make sure there is sufficient back pressure in
the system to maintain a full pipe.
3.3.3 CLAMP-ON TRANSDUCER MOUNTING MODES
Controlotron clamp-on transducers support Direct or Reflect mounting modes. The computer
recommends a mounting mode after analyzing your pipe and liquid data entries. However,
you can install clamp-on transducers in the way that best suits your application and the trans-
ducer type you purchased.
REFLECT MOUNT
(Pipe shown in Top View for ease in visualizing sonic path)
Upstream
Transducer
Sonic Path
Pipe
Downstream
Transducer
END VIEW OF PIPE
(Horizontal Plane)
Transducer located
at 9 o'clock
Transducer located
at 3 o'clock
Summary of Contents for SITRANS FUH1010PVX
Page 2: ......
Page 6: ......
Page 14: ......
Page 28: ......
Page 130: ......
Page 186: ......
Page 187: ...Siemens Hardware ...
Page 188: ......
Page 189: ...Siemens Hardware ...
Page 190: ......
Page 191: ...Siemens Hardware ...
Page 192: ......
Page 193: ...Siemens Hardware ...
Page 194: ......
Page 195: ...Siemens Hardware ...
Page 196: ...1010N 5 7 INSTALLATION DRAWING ANALOG INPUT MODULE 21614 C ...
Page 201: ...1011HNS 8 TRANSDUCER PART NUMBER L H W SIZE C D SIZE A B 21614 C Siemens Hardware ...
Page 202: ......
Page 203: ...Siemens Hardware ...
Page 204: ......
Page 206: ......
Page 214: ......
Page 225: ...Siemens Hardware ...