Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[units]
(units register)
Value range /
Setting options
Access
level
9110
Float / 4
Upper range
value mass flow
Upper mass flow value
that is mapped to the
upper nominal range
boundary selected by
Current mode (9106).
Applicable if Process
value (9102) = 0.
0.2 • max.
mass flow
[kg/s]
(7400)
-
Read /
write
9112
Float / 4
Lower range
value mass flow
Lower mass flow value
that is mapped to the
lower nominal range
boundary selected by
Current mode (9106).
Applicable if Process
value (9102) = 0.
0.0
[kg/s]
(7400)
-
Read /
write
9170
Float / 4
Upper range
value density
Upper process density
value that is mapped to
the upper nominal
range boundary selec‐
ted by Current mode
(9106). Applicable if
Process value (9102) =
2.
Max. density
[kg/m
3
]
(7600)
-
Read /
write
9172
Float / 4
Lower range
value density
Lower process density
value that is mapped to
the lower nominal
range boundary selec‐
ted by Current mode
(9106). Applicable if
Process value (9102) =
2.
0.08
[kg/m
3
]
(7600)
-
Read /
write
9174
Float / 4
Upper range
value tempera‐
ture
Upper medium temper‐
ature value that is map‐
ped to the upper nomi‐
nal range boundary se‐
lected by Current mode
(9106). Applicable if
Process value (9102) =
3.
Max. medium
temperature
[°C]
(7700)
-
Read /
write
9176
Float / 4
Lower range
value tempera‐
ture
Lower medium temper‐
ature value that is map‐
ped to the lower nomi‐
nal range boundary se‐
lected by Current mode
(9106). Applicable if
Process value (9102) =
3.
Min. medium
temperature
[°C]
(7700)
-
Read /
write
MODBUS commands
4.10 Modbus holding registers tables
FCT030 Modbus (From firmware 4.0)
94
Function Manual, 06/2018, A5E39931813-AB