Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[units]
(units register)
Value range /
Setting options
Access
level
9350
Unsigned / 4
Alarm items 5
Bit encoded selection
of alarm items that im‐
pact the output. See
if Status mode = 1.
0
Read /
write
9356
Unsigned / 4
Alarm items 8
Bit encoded selection
of alarm items that im‐
pact the output. See
if Status mode = 1.
0
Read /
write
10256
Unsigned / 4
Alarm items 9
Bit encoded selection
of alarm items that im‐
pact the output. See
if Status mode = 1.
0
Read /
write
9354
Unsigned / 4
Alarm items 7
Bit encoded selection
of alarm items that im‐
pact the output. See
if Status mode = 1.
0
Read /
write
9352
Unsigned / 4
Alarm items 6
Bit encoded selection
of alarm items that im‐
pact the output. Mainly
simulation alarms. See
if Status mode = 1.
0
Read /
write
9359
Unsigned / 2
Polarity
Logical polarity of sta‐
tus output.
0
● 0: Active high level
● 1: Active low level
Read /
write
9360
Float / 4
On delay
Time to delay the lead‐
ing edge of the output.
0.0
[s]
0.0 - 100.0
Read /
write
9362
Float / 4
Off delay
Time to delay the trail‐
ing edge of the output.
0.0
[s]
0.0 - 100.0
Read /
write
7162
Unsigned / 2
Forced value
Forced value when
forcing is active.
0
● 0
● 1
Read /
write
MODBUS commands
4.10 Modbus holding registers tables
FCT030 Modbus (From firmware 4.0)
118