Preface
Basic Functions
6
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Quantity structure
Explanations concerning the NC/PLC interface are based on the absolute maximum number of sequential
components:
• Mode groups (DB11)
• Channels (DB21, etc.)
• Axes/spindles (DB31, etc.)
Data types
The following elementary data types are used in the control system:
SINUMERIK 828D system performance (region)
Type
Meaning
Value range
INT
Signed integers
-2147483648 ... +2147483647
REAL
Figures with decimal point acc. to IEEE
±(2,2*10
-308
… 1,8*10
+308
)
BOOL
Truth values TRUE (1) and FALSE (0)
1, 0
CHAR
ASCII characters
Corresponding to code 0 to 255
STRING
Character string, number of characters in [...]
Maximum of 200 characters (no special
characters)
AXIS
Axis names only
All axis identifiers in the channel
FRAME
Geometrical parameters for moving, rotating, scaling, and
mirroring
Arrays can only be formed from similar elementary data types. Up to 3-dimensional arrays are possible.
PPU240.2 / 241.2
PPU 260.2 / 261.2
PPU 280.2 / 281.2
BASIC T
BASIC M
T
M
T
M
System performance
Basic quantity of axes/spindles
3
4
3
4
3
4
Max. number of axes/spindles
5
5
6
6
8
6
Max. number of interpolating axes
4
4
4
4
4
4
Max. number: Channels / mode groups
1/1
1/1
1/1
1/1
1/1
1/1
Min. block change time
∼ 9 ms
∼ 9 ms
∼ 6 ms
∼ 6 ms
∼ 6 ms
∼ 3 ms
Speed/current control cycle
125 µs
125 µs
125 µs
125 µs
125 µs
125 µs
CNC user memory (buffered)
1 MB
1 MB
3 MB
3 MB
5 MB
5 MB
CNC functions
Tool Management
●
●
●
●
●
●
Number of tools/cutting edges
80/160
80/160
128/256
128/256
256/512
256/512
Max. number of ASUBs (permanently
set)
2
2
2
2
2
2
TRANSMIT / TRACYL
○
○
○
○
○
○