Machine data
6.5.1.1
Axis/spindlespecific machine data
6.5.2
Setting data
6.5.2.1
Axis/spindle-specific setting data
6.5.3
Signals
6.5.3.1
Signals to axis/spindle
Number
Identifier: $MA_
Description
36042
FOC_STANDSTILL_DELAY_TIME
Delay time, standstill monitoring for
active
torque/force limiting
37000
FIXED_STOP_MODE
Travel to fixed stop mode
37002
FIXED_STOP_CONTROL
Sequence monitoring for travel to fixed stop
37010
FIXED_STOP_TORQUE_DEF
Fixed stop clamping torque default setting
37012
FIXED_STOP_TORQUE_RAMP_TIME
Time until the modified torque limit is reached
37020
FIXED_STOP_WINDOW_DEF
Default for fixed stop monitoring window
37030
FIXED_STOP_THRESHOLD
Threshold for fixed stop detection
37040
FIXED_STOP_BY_SENSOR
Fixed stop detection via sensor
37050
FIXED_STOP_ALARM_MASK
Enabling the fixed stop alarms
37052
FIXED_STOP_ALARM_REACTION
Reaction to fixed stop alarms
37060
FIXED_STOP_ACKN_MASK
Monitoring of PLC acknowledgments for travel to fixed
stop
37070
FIXED_STOP_ANA_TORQUE
Torque limit on fixed stop approach for analog drives
37080
FOC_ACTIVATION_MODE.
Initial setting of the modal torque/force limiting
Number
Identifier: $SA_
Description
43500
FIXED_STOP_SWITCH
Selection of travel to fixed stop
43510
FIXED_STOP_WINDOW
Fixed stop clamping torque
43520
FIXED_STOP_TORQUE
Fixed stop monitoring window
Signal name
SINUMERIK 840D sl
SINUMERIK 828D
Acknowledge fixed stop reached
DB31, ... .DBX1.1
DB380x.DBX1.1
Sensor for fixed stop
DB31, ... .DBX1.2
DB380x.DBX1.2