D1: Diagnostics tools
5.3 Service overview
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
281
Smoothed actual current value
Display of the smoothed actual current value. The torque-generating actual current value is smoothed by a PT1
element with parameterizable time constants.
Unit: %
100 % corresponds to the maximum current of the power section.
Display corresponds to machine data:
MD1708 $MD_ACTUAL_CURRENT (smoothed actual current value).
Motor temperature
Display of motor temperature measured via temperature sensors.
Unit: Degrees Celsius
Display corresponds to machine datum:
MD1702 $MD_MOTOR_TEMPERATURE (motor temperature).
Speed setpoint filter 1
Status display of speed setpoint smoothing function.
Display corresponds to IS DB31, ... DBX92.3 ("Speed setpoint smoothing active") and is shown in an updated
form as of software version 6.3 and later.
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
2. Torque Limit
Display of active torque limit
State 0: Torque limit 1 is active.
State 1: Torque limit 2 is active.
Display corresponds to IS DB31, ... DBX92.2
("Torque limit 2 active").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
State 0:
No speed setpoint smoothing is active.
State 1:
Smoothing of the speed setpoint as requested by the PLC using IS DB31, ...
DBX20.3
("Speed setpoint smoothing") takes effect because speed setpoint filter 1 is
configured as the low pass.