Z1: NC/PLC interface signals
19.2 Axis monitoring, protection zones (A3)
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1655
Signal state 0 or
edge change
1 → 0
No limitation active.
Corresponding to .... MD35100 $MA_SPIND_VELO_LIMIT (max. spindle speed)
SD43220 $SA_SPIND_MAX_VELO_G26 (prog. spindle speed limiting G26)
MD43230 $SA_SPIND_MAX_VELO_LIMIT (prog. spindle speed limiting G96/G961)
DB31, ...
DBX12.0 - DBX12.1 Hardware limit switches plus and minus
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
A switch can be mounted at each end of the travel range of a machine axis which will cause a signal
"hardware limit switch plus or minus" to be signaled to the NC via the PLC if it is actuated.
If the signal is recognized as set, alarm 021614 "hardware limit or -" is output and the axis is
decelerated immediately.
The braking/deceleration type is defined using the machine data:
MD36600 $MA_BRAKE_MODE_CHOICE (braking behavior at the hardware limit switch)
If the controller enable is withdrawn at the same time as the "hardware limit switch" signal, then the
axis responds as described in Chapter A2 ("various interface signals").
Signal state 0 or
edge change
1 → 0
Normal condition - a hardware limit switch has not been actuated.
Corresponding to .... MD36600 $MA_BRAKE_MODE_CHOICE (deceleration behavior when the hardware limit switch
responds)
DB31, ...
DBX12.2 - DBX12.3 2nd software limit switch plus or minus
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
2nd software limit switch for the plus and minus directions is effective.
1st software limit switch for the plus and minus directions is not effective.
In addition to the 1st software limit switches (plus and minus), the 2nd software limit switches (plus
and minus) can be activated using these interface signals.
The position is defined using machine data:
MD36130 $MA_POS_LIMIT_PLUS2 (2nd software limit switch plus)
and
MD36120 $MA_POS_LIMIT_MINUS2 (2nd software limit switch minus)
.
Signal state 0 or
edge change
1 → 0
1st software limit switch for the plus and minus directions is effective.
2nd software limit switch for the plus and minus directions is not effective.
Corresponding to .... MD36110 $MA_POS_LIMIT_PLUS (1st software limit switch plus)
MD36130 $MA_POS_LIMIT_PLUS2 (2nd software limit switch plus)
MD36100 $MA_POS_LIMIT_MINUS (1st software limit switch minus)
MD36120 $MA_POS_LIMIT_MINUS2 (2nd software limit switch minus)
DB31, ...
DBX3.6
Velocity/spindle speed limitation