Z1: NC/PLC interface signals
19.6 Mode group, channel, program operation, reset response
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1667
19.6
Mode group, channel, program operation, reset response (K1)
19.6.1
Signals to mode group (DB11)
DB11
DBX0.0
AUTOMATIC mode
Edge evaluation: No
Signal(s) updated: Cyclic
Signal state 1 or
edge change
0 → 1
AUTOMATIK mode is selected by the PLC program.
Signal state 0 or
edge change
1 → 0
AUTOMATIK mode is not selected by the PLC program.
Signal irrelevant for
...
DB11 DBX0.4 (operating mode, changeover inhibit) = 1
Corresponding to ...
DB11 DBX6.0 (active AUTOMATIC mode)
DB11
DBX0.1
MDA mode
Edge evaluation: No
Signal(s) updated: Cyclic
Signal state 1 or
edge change
0 → 1
MDA mode is selected by the PLC program.
Signal state 0 or
edge change
1 → 0
MDA mode is not selected by the PLC program.
Signal irrelevant for
...
DB11 DBX0.4 (operating mode, changeover inhibit) = 1
Corresponding to ...
DB11 DBX6.1 (active MDA mode)
DB11
DBX0.2
JOG mode
Edge evaluation: No
Signal(s) updated: Cyclic
Signal state 1 or
edge change
0 → 1
JOG mode is selected by the PLC program.
Signal state 0 or
edge change
1 → 0
JOG mode is not selected by the PLC program.
Signal irrelevant for
...
DB11 DBX0.4 (operating mode, changeover inhibit) = 1
Corresponding to ...
DB11 DBX6.2 (active JOG mode)