Spindle monitoring
16.8.1
Permissible speed ranges
The spindle monitoring functions and the currently active functions (G94, G95, G96, G961, G97, G971, G33,
G34, G35, G331, G332, etc.) define the permissible speed ranges of the spindle.
Figure 16-9 Ranges of spindle monitoring functions/speeds
6SLQGOHVSHHG
0D[LPXPHQFRGHUOLPLWIUHTXHQF\
0D[LPXPVSLQGOHVSHHG
0LQLPXPVSLQGOHVSHHGIRUFXUUHQWJHDUVWHS
,6$[LV6SLQGOHVWDWLRQDU\QQPLQ
6SHHGUDQJHRIVSLQGOH
RUVSLQGOHFKXFN
0D[LPXPVSLQGOHVSHHGIRUFXUUHQWJHDUVWHS
3URJUDPPDEOHVSLQGOHVSHHGOLPLW/,06
3URJUDPPDEOHPLQLPXPVSLQGOHVSHHG*
6SHHGUDQJHRIFXUUHQWJHDUVWHS
6SHHGUDQJHRIFXUUHQWJHDUVWHS
OLPLWHGE\*DQG*
6SHHGUDQJHRIFXUUHQWJHDUVWHSDW
FRQVWDQWFXWWLQJUDWH**DQG*
,6+RPHG6\QFKURQL]HG
6SLQGOHLVVWDWLRQDU\