V1: Feedrates
17.4 Feedrate control
Basic Functions
1410
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
• When the operating mode is changed from AUTO to JOG, the programmed dynamic response changes
remain valid.
• With reset, the last programmed value remains for the part program specifications. The settings for main-run
interpolations do not change.
• Block search:
The last end-of-motion criterion programmed for an axis is collected and output in an action block. The last
block with a programmed end-of-motion criterion that was processed in the search run serves as a container
for all programmed end-of-motion criteria for all axes.