Technical data
10.1 Technical data for CU230P-2
Frequency inverters with Control Units CU230P-2 HVAC, CU230P-2 DP, CU230P-2 CAN
304
Operating Instructions, 01/2011, FW 4.4, A5E02430659B AD
Feature
Data / explanation
PTC: Short-circuit monitoring < 20 Ω, overtemperature 1650 Ω
KTY84: Short-circuit monitoring < 50 Ω, wire-break: > 2120 Ω
Motor temperature sensor
ThermoClick sensor with dry contact
USB interface
Mini 5-pole USB
MMC card
Recommendation: 6SL3254-0AM00-0AA0
Memory card (optional)
SD card
Recommendation: 6SL3254-0AM00-0AA0
Dimensions (WxHxD)
73 mm × 199 mm × 65.5 mm
Weight
0.61 kg
0 °C … 60 °C
For operation without operator panel
Operating temperature
0 °C … 50 °C
For operation with operator panel
Storage temperature
- 40°C … 70 °C%
Relative humidity
< 95 %
Condensation must not be allowed to form
V/f control for motor speeds between 0 rpm and 210000 rpm:
•
Linear V/f control,
•
Linear V/f control with FCC,
•
Linear V/f control with ECO mode,
•
Quadratic V/f control,
•
Multipoint V/f control,
•
V/f control for applications in the textile industry,
•
V/f control with FCC for applications in the textile industry,
•
V/f control with independent voltage setpoint,
Open-loop/closed-loop
control procedure
Vector control for motor speeds between 0 rpm and 14400 rpm:
•
Speed control without encoder
•
Torque control without encoder
The control terminals on the Control Unit are galvanically isolated from the supply voltage
(PELV).