Rostock MAX v2 Assembly Guide – 4thEd.
Once the fan is installed, attach the ring terminals on the fan to the terminal block as shown
below. Make sure that the black wire goes to the “V-” section and the red wire goes to the “V+”
section.
Now you need to attach the green wire from the power
supply to the center connector on the IEC connector and the
white wire from the power supply to the right connector.
Connect the black wire from the power supply to the
center connector on the power switch.
Using two black nylon thumbscrews, attach the
power supply cover to the vertical support.
This would be a good time to test the power supply. Plug in the AC cord and turn on the power
switch. The large cooling fan should start running. If it doesn't, turn the power switch off, unplug the
power cord and double-check your wiring.
Checkpoint Video #5
6 – Assembling the Base – 54
Fig. 6.6-6: Fan wired in!
Fig. 6.6-7: IEC plug & switch wired.
Fig. 6.6-8: Power supply install complete.