Numeric Measurement Modes
R&S
®
EVSF1000
51
User Manual 1178.6410.02 ─ 05
Clearance
Defines the clearance carrier as a frequency offset from the nominal frequency in the
opposite direction to the course carrier.
1F Offset
For single frequency measurements only:
Defines an offset of the measured frequency to the nominal frequency.
Remote command:
Find Carrier
For manual carrier determination only:
Determines the carrier frequencies automatically, but only once. The frequencies do
not change automatically if the input signal changes.
Remote command:
Carrier Thresh
Defines a threshold for automatic carrier determination (once or continuously). The
measured power level at a frequency other than the current carrier must exceed this
level before the carrier frequency is adapted. This is useful for noisy or unstable sig-
nals so the carrier frequencies do not change unnecessarily often due to minor distur-
bances.
Remote command:
Upper Freq
The course and clearance carriers are defined as offsets to either side of the center
frequency. Which frequency is considered to be the course carrier - the upper or lower
frequency - depends on the used standard and the country it is used in. Thus, you can
swap the carrier definition if necessary.
Remote command:
Channel Frequency Configuration (CH FREQ)
Access VNC
: [q]
The channel frequency determines the nominal frequency at which the measurement is
performed. For some avionics standards, the channels are associated with specific fre-
quencies. (See
Chapter A, "ILS Channel Frequency List"
ILS Localizer and ILS Glidepath (GP) Modes