Remote Commands
R&S
®
EVSF1000
240
User Manual 1178.6410.02 ─ 05
GET_MEASFREQ
Query the measured value of delta RF carrier frequency to set RF frequency in "COM"
mode.
Return values:
<freq>
Delta between measured and set RF frequency.
Default unit: kHz
GET_TX1_MEASFREQ
Query the measured value of delta TX1 RF carrier frequency to set RF frequency in
"COM" mode.
Return values:
<freq>
Delta between measured TX1 frequency and set RF frequency.
Default unit: kHz
GET_TX2_MEASFREQ
Query the measured value of delta TX2 RF carrier frequency to set RF frequency in
"COM" mode.
Return values:
<freq>
Delta between measured TX2 frequency and set RF frequency.
Default unit: kHz
GET_ONE_AMMOD
Query the AM modulation depth in "COM" mode.
Return values:
<mod. depth>
AM modulation depth
Default unit: %
Manual operation:
See
GET_TX1_AMMOD
Query the TX1 AM modulation depth of 2F signal in "COM" mode.
Parameters:
<mod. depth>
TX1 AM modulation depth of 2F signal.
Default unit: %
Manual operation:
See
GET_TX2_AMMOD
Query the TX2 AM modulation depth of 2F signal in "COM" mode.
COM Mode