![Rohde & Schwarz EVSF1000 User Manual Download Page 243](http://html.mh-extra.com/html/rohde-and-schwarz/evsf1000/evsf1000_user-manual_1477818243.webp)
Remote Commands
R&S
®
EVSF1000
243
User Manual 1178.6410.02 ─ 05
GBAS:FREQRF?
GBAS:FREQRF
<Freq>
Gets or sets the channel frequency that determines the carrier frequency at which the
GBAS measurement is performed.
Parameters:
<Freq>
RF frequency
The VHF data broadcast is defined for carrier frequencies within
the range of 108.025
MHz to 117.950
MHz with a channel spac-
ing of 25
kHz.
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
GBAS:LEV?
<Slot>
LA?
<Slot>
Queries the arithmetic average of the burst power level measured over the period of
the synchronization and ambiguity resolution field of the burst.
If no burst was detected, the arithmetic average of the noise power is returned.
Parameters:
<Slot>
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7
Selects the slot for which results are queried.
Return values:
<Freq>
Signal level
Default unit: dBm
Example:
GBAS:LEV? 2
Usage:
Query only
Manual operation:
See
"Burst Level Average (Av [dBm])"
MODE_GBAS
This command starts GBAS mode.
Return values:
<State>
READY.
Command was executed successfully.
GBAS/ SCAT-I Mode