ALL
All values of the current measurement mode are sent as comma
separated text, using actual units.
MEDIUM
A fixed selection of parameters is exported.
SHORT
A short fixed selection of parameters is exported.
RAW
Only the non-interpreted measurement values from the bit-
stream in binary format are exported
+MSG
Optional: If specified, the message data is included in the data
stream, surrounded by curly brackets { }
<RX-Board>
Selects the RX board for which results are exported.
1
RX board 1 selected
2
RX board 2 selected
1+2
Both RX boards selected
<Slots>
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7
Selects one or more slots for which results are exported. Multi-
ple slots can be selected.
Return values:
<State>
READY.
The command was executed successfully.
Example:
GBAS:STREAM RAW,1+2,3
Sends the data for slot 3 on both receiver boards as binary data
to the USB output.
Example:
GBAS:STREAM ALL,1,01234567
Outputs the evaluated data (without the message data) for all
slots on receiver board 1.
Example:
GBAS:STREAM ALL+MSG,1,0
Outputs all evaluated data, including message data, for slot 0 on
receiver board 1.
GBAS:STOPSTREAM
This command terminates the data stream for both RX Boards in GBAS mode.
Return values:
<State>
READY.
The command was executed successfully.