Data Management
R&S
®
EVSF1000
161
User Manual 1178.6410.02 ─ 05
List
Selects a specific data set list (1 to 999, the list number is shown in the softkey).
Remote command:
Clear List
Deletes all entries in the current list.
Remote command:
Time
Specifies how often an entry is appended to the data list. Enter the time in millisec-
onds.
Note that the minimum spacing between two values is defined by the availability of
measurement result values (see
Chapter 6.1.4.4, "Setting the Measurement Time
on page 55). If more values are available than are stored, that is: "Time" >
Setting the Measurement Time (MTime)
, the calculated values are averaged to obtain
only the required number of results.
In GBAS/SCAT-I mode, one record is stored for each slot, in a time interval of 62.5
ms,
as long as recording is active. The time interval cannot be edited.
Data selection (Sel, not GBAS/SCAT-I mode)
By default, the whole data set is recorded. You can configure the scope of the data to
be displayed and exported. For details on the individual data sets, see the remote com-
mand (
"All"
Includes all EVSF1000 and R&S EVS300 values.
"Full"
Compatible to R&S EVS300.
"Medium"
A reduced set of values
"Short"
A minimum set of values
Remote command:
Data selection (Select, GBAS/SCAT-I mode only)
By default, the whole data set for every slot is recorded. You can configure the scope
of the data to be displayed and exported. For details on the individual data sets, see
the remote command (
Parameter ← Data selection (Select, GBAS/SCAT-I mode only)
Defines which parameters are stored for each slot.
"All"
Includes all EVSF1000 and R&S EVS300 values
Recording Measurement Data