Remote Commands
R&S
®
EVSF1000
208
User Manual 1178.6410.02 ─ 05
LLZ_DEMFREQS_OFFSET_AUTOMAN?
LLZ_DEMFREQS_OFFSET_AUTOMAN
<Mode>
Gets or sets the mode of the demodulator frequency offset in "ILS LOC" mode.
Parameters:
<Mode>
AUTO
Sets the demodulator frequenecy offset automatically.
MANUAL
Sets the demodulator frequency offset manually.
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
LLZ_DEMFREQS_OFFSET_LOWERFREQ?
LLZ_DEMFREQS_OFFSET_LOWERFREQ
<Freq. Offset>
Gets or Sets the demodulator lower frequency offset in "ILS LOC" mode.
Parameters:
<Freq. Offset>
Lower frequency offset
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
LLZ_DEMFREQS_OFFSET_UPPERFREQ
LLZ_DEMFREQS_OFFSET_UPPERFREQ
<Freq. Offset>
Gets or Sets the demodulator upper frequency offset in "ILS LOC" mode.
Parameters:
<Freq. Offset>
Upper frequency offset
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
ILS Localizer (LOC) and Glidepath (GP) Modes