GBAS/SCAT-I Mode (Options R&S
EVSG-K4/-K5)
R&S
®
EVSF1000
122
User Manual 1178.6410.02 ─ 05
As opposed to the "Sequence" view, the "Frame" view displays the results of a single
frame only. By default, the most recently measured frame T is displayed. To display the
results for a different frame, use the
function.
The display is updated each time a complete frame has been measured, that is: every
500
ms. To freeze the current display for evaluation, you can pause the view update
on page 132). Data recording and streaming, however, continue as
usual. When updating is resumed, the displayed results in the view are updated.
The "Frame" view contains two different displays:
●
Chapter 8.4.2.1, "Frame Power Vs. Time Diagram"
●
Chapter 8.4.2.2, "Frame Results Table"
8.4.2.1
Frame Power Vs. Time Diagram
The power vs. time diagram displays the measured power per time, normalized to the
PPS signal. The fixed slot grid defined by the PPS (reference) signal is indicated by
vertical lines in the diagram. In addition to the time in milliseconds, the slot label A to H
is indicated on the x-axis. The time axis always starts at 0
seconds or 500
millisec-
onds.
GBAS / SCAT-I Measurement Views and Results