Remote Commands
R&S
®
EVSF1000
266
User Manual 1178.6410.02 ─ 05
Return values:
<NoEntries>
integer
Number of entries in the active list.
Range:
0 to 1 000 000
SAVEACTIVELIST2USB
<Filename>
This command copies the active list to a connected USB storage device as a
.csv
file.
The file name is set automatically (e.g
llz_rx1_list9.csv
).
Note that this command is time-consuming for long lists (max. 1
000
000 entries).
To reduce the amount of logged data, restrict it to specific parameters.
Parameters:
<Filename>
string
Path, file name and extension of the file on the USB device to
which the data is stored: Note that a specified path must already
exist on the USB device, otherwise an error occurs.
Return values:
<EventResult>
READY.
The command was executed successfully.
ERROR
An error occurred; command was not successful.
Example:
SETACTIVELIST 2
//Defines list 2 as the active list.
SAVEACTIVELIST2USB
Manual operation:
See
SELECTLISTPARAM
<Params>
This command selects the parameters to be logged.
Parameters:
<Params>
Set of parameters to be included in data log.
ALL
All parameters are selected for logging.
FULL
The selected parameters are compatible to EVS300.
MEDIUM
A reduced set of parameters is selected.
SHORT
A minimum set of parameters is selected.
Example:
//Select all parameters for logging
SELECTLISTPARAM ALL
Manual operation:
See
"Data selection (Sel, not GBAS/SCAT-I mode)"
Data Management