No. Result
Description
Possible Causes/Action
54
ID sensor
coefficient (K5)
maximum/
minimum error
When the K5 is more
than the value of
SP3-362-003 or less
than the value of
SP3-362-004, the error
54 is displayed.
• ID sensor pattern density is too high or low.
• ID sensor or shutter is defective.
Same as 53
55
Gamma error:
Maximum
Gamma is out of range.
5.0 < Gamma
• ID sensor pattern density is too high.
• Hardware defective.
Same as 53
56
Gamma error:
Minimum
Gamma is out of range.
Gamma < 0.15
• ID sensor pattern density is too low.
• Hardware defective.
1. Same as 53
2. Replace the toner supply pump unit.
57
Vk error:
Maximum
Vk is out of range.
150 < Vk
• ID sensor pattern density is too low.
• Hardware defective.
Same as 53
58
Vk error:
Minimum
Vk is out of range.
Vk < –150
• ID sensor pattern density is too high.
• Background dirty
• Hardware defective
Same as 53
59
Sampling data
error during
gamma
correction
Not enough data can be
sampled during the
gamma correction.
• ID sensor pattern density is too high or low.
• Hardware defective
Same as 53
99
Unexpected
error
Process control fails.
• Power Failure
Check the power source.
6. Troubleshooting
614
Summary of Contents for Z-P2
Page 1: ...Model Z P2 Machine Codes M257 Field Service Manual April 2015 ...
Page 2: ......
Page 30: ...1 Product Information 28 ...
Page 73: ...9 Install the securing holder E 10 Reassemble the machine Tray Heater 71 ...
Page 86: ...3 Preventive Maintenance 84 ...
Page 92: ...5 Left cover B Right Cover 1 Open the duplex unit A 4 Replacement and Adjustment 90 ...
Page 128: ...5 Open the upper cover A 4 Replacement and Adjustment 126 ...
Page 131: ...4 The left stay A x 4 5 Rear holder bracket A x 2 Image Transfer 129 ...
Page 139: ...3 Remove the two screws 4 ID sensor board bracket A x 1 Image Transfer 137 ...
Page 141: ...4 Exit the SP mode Image Transfer 139 ...
Page 146: ...2 Temperature Humidity sensor A x 1 x 1 4 Replacement and Adjustment 144 ...
Page 187: ...3 Bracket A x 1 4 Release the paper feed unit A x 1 Paper Feed 185 ...
Page 201: ...5 Inner left upper cover page 94 6 Paper exit unit holder A x 1 Paper Exit 199 ...
Page 211: ...6 Release the left arm A x 1 Duplex Unit 209 ...
Page 215: ...3 Duplex lower guide plate A 4 Duplex upper guide plate A x 7 Duplex Unit 213 ...
Page 220: ...8 Right and left arms A x 2 each 4 Replacement and Adjustment 218 ...
Page 221: ...9 Duplex By pass motor bracket with the frame A x 6 10 Guide plate A x 4 Duplex Unit 219 ...
Page 245: ...5 Disconnect the connector 6 Disconnect the six connectors x 1 Electrical Components 243 ...
Page 254: ...4 Replacement and Adjustment 252 ...
Page 564: ...5 System Maintenance Reference 562 ...
Page 637: ...Model Z P2 Machine Codes M257 Appendices February 2015 ...
Page 638: ......
Page 640: ...2 ...
Page 648: ...1 Appendix Specifications 10 ...
Page 652: ...MEMO 14 ...
Page 653: ...MEMO 15 ...
Page 654: ...MEMO 16 EN ...