3531
[No-use ProCon Set]
Adjusts the threshold for the process control at stand-by.
When the current condition has changed by more than the values of these SPs when
compared with the conditions at the previous operation, the process control at stand-
by is executed.
3-531-001 No-Use Time Set
*ENG [0 to 1440 / 360 / 1 minute/step]
3-531-002 Temperature Range
*ENG [0 to 99 / 10 / 1 deg/step]
3-531-003 RHumidity Change
*ENG [0 to 99 / 50 / 1 %RH/step]
3-531-004 AHumidity Change
*ENG [0 to 99 / 6 / 1 g/m
3
/step]
3-531-005 Max. Exe. Number
*ENG Adjusts the maximum execution time for the
process control at stand-by.
[0 to 99 / 10 / 1 time/step]
3611
[DevGamma:Dspl/Set]
3-611-001 Bk (Current)
*ENG Displays the current development gamma for
Bk
[0 to 5 / 0 / 0.01 mg/cm
2
/kV /step]
3-611-002 C (Current)
*ENG Displays the current development gamma for
C/M/Y.
[0 to 5 / 0 / 0.01 mg/cm
2
/kV /step]
3-611-003 M (Current)
*ENG
3-611-004 Y (Current)
*ENG
3-611-005 Bk(TargetDisplay)
*ENG Displays the target development gamma for Bk.
[0 to 5 / 0.85 / 0.01 mg/cm
2
/kV /step]
3-611-006 C (TargetDisplay)
*ENG Displays the target development gamma for
C/M/Y.
[0 to 5 / 0.85 / 0.01 mg/cm
2
/kV /step]
3-611-007 M (TargetDisplay)
*ENG [0 to 5 / 0.8 / 0.01 mg/cm
2
/kV /step]
3-611-008 Y (TargetDisplay)
*ENG [0 to 5 / 0.77 / 0.01 mg/cm
2
/kV /step]
3800
[Toner Collection Bttl Full]
Engine SP Mode Tables - SP3000
417
Summary of Contents for Z-P2
Page 1: ...Model Z P2 Machine Codes M257 Field Service Manual April 2015 ...
Page 2: ......
Page 30: ...1 Product Information 28 ...
Page 73: ...9 Install the securing holder E 10 Reassemble the machine Tray Heater 71 ...
Page 86: ...3 Preventive Maintenance 84 ...
Page 92: ...5 Left cover B Right Cover 1 Open the duplex unit A 4 Replacement and Adjustment 90 ...
Page 128: ...5 Open the upper cover A 4 Replacement and Adjustment 126 ...
Page 131: ...4 The left stay A x 4 5 Rear holder bracket A x 2 Image Transfer 129 ...
Page 139: ...3 Remove the two screws 4 ID sensor board bracket A x 1 Image Transfer 137 ...
Page 141: ...4 Exit the SP mode Image Transfer 139 ...
Page 146: ...2 Temperature Humidity sensor A x 1 x 1 4 Replacement and Adjustment 144 ...
Page 187: ...3 Bracket A x 1 4 Release the paper feed unit A x 1 Paper Feed 185 ...
Page 201: ...5 Inner left upper cover page 94 6 Paper exit unit holder A x 1 Paper Exit 199 ...
Page 211: ...6 Release the left arm A x 1 Duplex Unit 209 ...
Page 215: ...3 Duplex lower guide plate A 4 Duplex upper guide plate A x 7 Duplex Unit 213 ...
Page 220: ...8 Right and left arms A x 2 each 4 Replacement and Adjustment 218 ...
Page 221: ...9 Duplex By pass motor bracket with the frame A x 6 10 Guide plate A x 4 Duplex Unit 219 ...
Page 245: ...5 Disconnect the connector 6 Disconnect the six connectors x 1 Electrical Components 243 ...
Page 254: ...4 Replacement and Adjustment 252 ...
Page 564: ...5 System Maintenance Reference 562 ...
Page 637: ...Model Z P2 Machine Codes M257 Appendices February 2015 ...
Page 638: ......
Page 640: ...2 ...
Page 648: ...1 Appendix Specifications 10 ...
Page 652: ...MEMO 14 ...
Page 653: ...MEMO 15 ...
Page 654: ...MEMO 16 EN ...