5-866-001 Report Validity
*CTL
Enables or disables the e-mail alert.
[0 or 1 / 0 / – /step]
0: Enable, 1: Disable
5-866-005 Add Date Field
*CTL
Adds or does not add the date field to the
header of the alert mail.
[0 or 1 / 0 / – /step]
0: Not added, 1: Added
5869
[RAM Disk Setting]
5-869-001 Mail Function
*CTL
[0 to 1 / 0 / 1/step]
0: ON, 1: OFF
Enables or disables the e-mail transfer function. This SP sets the RAM disk size for the
e-mail transfer function.
5870
[Common Key Info Writing]
5-870-001 Writing
*CTL
Rewrites the common certification used
for the @Remote.
5-870-003 Initialize
*CTL
-
Initializes the set certification.
When the GW controller board is replaced with a new one for repair, you must
execute the "Initiralize (-003)" and "Writing (-001)" just after the new board
replacement.
NOTE: Turn off and on the main power switch after the "Initiralize (-003)" and
"Writing (-001)" have been done.
5-870-004 Writing: 2048bit
*CTL
-
5873
[SD Card Appli Move]
5-873-001 Move Exec
This SP copies the application programs from the original SD card
in SD card slot 2 to an SD card in SD card slot 1.
Engine SP Mode Tables - SP5000
465
Summary of Contents for Z-P2
Page 1: ...Model Z P2 Machine Codes M257 Field Service Manual April 2015 ...
Page 2: ......
Page 30: ...1 Product Information 28 ...
Page 73: ...9 Install the securing holder E 10 Reassemble the machine Tray Heater 71 ...
Page 86: ...3 Preventive Maintenance 84 ...
Page 92: ...5 Left cover B Right Cover 1 Open the duplex unit A 4 Replacement and Adjustment 90 ...
Page 128: ...5 Open the upper cover A 4 Replacement and Adjustment 126 ...
Page 131: ...4 The left stay A x 4 5 Rear holder bracket A x 2 Image Transfer 129 ...
Page 139: ...3 Remove the two screws 4 ID sensor board bracket A x 1 Image Transfer 137 ...
Page 141: ...4 Exit the SP mode Image Transfer 139 ...
Page 146: ...2 Temperature Humidity sensor A x 1 x 1 4 Replacement and Adjustment 144 ...
Page 187: ...3 Bracket A x 1 4 Release the paper feed unit A x 1 Paper Feed 185 ...
Page 201: ...5 Inner left upper cover page 94 6 Paper exit unit holder A x 1 Paper Exit 199 ...
Page 211: ...6 Release the left arm A x 1 Duplex Unit 209 ...
Page 215: ...3 Duplex lower guide plate A 4 Duplex upper guide plate A x 7 Duplex Unit 213 ...
Page 220: ...8 Right and left arms A x 2 each 4 Replacement and Adjustment 218 ...
Page 221: ...9 Duplex By pass motor bracket with the frame A x 6 10 Guide plate A x 4 Duplex Unit 219 ...
Page 245: ...5 Disconnect the connector 6 Disconnect the six connectors x 1 Electrical Components 243 ...
Page 254: ...4 Replacement and Adjustment 252 ...
Page 564: ...5 System Maintenance Reference 562 ...
Page 637: ...Model Z P2 Machine Codes M257 Appendices February 2015 ...
Page 638: ......
Page 640: ...2 ...
Page 648: ...1 Appendix Specifications 10 ...
Page 652: ...MEMO 14 ...
Page 653: ...MEMO 15 ...
Page 654: ...MEMO 16 EN ...