RD 500 RD51
Inverter Technical Data
5-1
DOK-RD500*RD51*******-IB04-EN-P
5
Inverter Technical Data
5.1
Technical Data for Size Classes A and B with Pulse
frequency f
p
= 4 kHz / 8 kHz
4 kHz
8 kHz
RD51.2
003
005
007
015
018
003
005
007
015
018
Rated motor output
1)
kW
3.0
5.5
7.5
15
18.5
2.2
4.0
5.5
11
15
Supply voltage DC 530 ... 670 V (±10 %)
2)
Output frequency Hz
0 - 250
0 - 500
Rated current
A 7.5
13
18
30
35
5.8
10
13
25
30
Peak current for t = 60 s A
9.8
17
23
39
46
7.5
13
17
33
39
t = 1 s A
13
22
31
51
60
9.9
17
22
43
51
t = 0.5 s A
15
26
36
60
70
12
20
26
50
60
Rated output S
N
kVA 4.9
8.6
12
20
23
3.8
6.6
8.6
16
20
Peak power for t = 60 s kVA 6.5
11
15
26
30
4.9
8.6
11
22
26
Supply voltage, 700 V DC (±10 %)
Output frequency Hz
0 - 250
0 - 500
Rated current
A 6
10
14
24
28
4.5
8
10
20
24
Peak current for t = 60 s A 7.8
13
18
31
36
5.9
10
13
26
31
t = 1 s A
10
17
24
41
48
7.7
14
17
34
41
t = 0.5 s A
12
20
28
48
56
9.0
16
20
40
48
Rated output S
N
kVA 4.9
8.2
12
20
23
3.7
6.6
8.2
16
20
Peak power for t = 60 s kVA 6.4
11
15
26
30
4.9
8.2
11
21
26
Ambient conditions, noise suppression level, interference immunity
Environmental class
3K3 according to DIN IEC 721-3-3 (ambient temperature 0 – 40 °C operation,
to 50 °C power reduction at 2.5 % per K)
Cooling air requirement
m³ / s
0.03
0.03
0.03
0.05
0.05
0.03
0.03
0.03
0.05
0.05
Power loss kW 0.15
0.2,
0.26
0.37
0.42
0.16
0.23
0.27
0.43
0.50
Radio int. sup. level/noise immunity
A 1 according to EN 55011 / EN 61800-3 (only with RZF line filter)
Mechanical design
Size classes
A
A
A
B
B
A
A
A
B
B
Degree of protection
IP 20 according to EN 60529 with connected plug
Weight of inverter for the various cooling types
D Plug-through cooler
kg
5.5
5.5
5.5
10.3
10.3
5.5
5.5
5.5
10.3
10.3
L Forced air cooling
kg
6.5
6.5
6.5
11.3
11.3
6.5
6.5
6.5
11.3
11.3
P heat dissipation panel
kg
5.0
5.0
5.0
9.8
9.8
5.0
5.0
5.0
9.8
9.8
1):
Max. permissible motor power based on 4-pin standard induction
motor
2):
Starting at an output voltage Ua >400 V, the rated current is linearly
reduced from 100 % to 83 % for Va = 480 V.
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......