RD 500 RD51
Operator Control and Visualization
7-5
DOK-RD500*RD51*******-IB04-EN-P
Copy Function
A copy function is integrated in the user panel. This allows a parameter
set to be saved in the user panel (P0733) and then transferred quickly into
another unit (P0732). In this case, only those parameters which are
accessible with the selected password level are transferred to the unit.
Note:
The parameter set can be saved in the operator panel after
start-up and after the drive has been optimized. This means
that when the AC drive converter is replaced, it can be quickly
recommissioned.
Password level 3 must be used to transfer (download) data
into the drive.
ESC
START
STOP
MON
ENTER
PROG
-
+
ALARM
ON
READY
P0733
P0732
AP520013DE00.FH9
Fig. 7-8: Copy function
Note:
After Copy, can be checked over Monitor copy-Status if faults
be arise at the transmission
Fault Acknowledgement
After a fault occurs, “Fault” is displayed in the operating display. The
cause of the fault and the fault time are displayed below this. After the
cause of the fault has been removed, it can be acknowledged using the
Esc
key of the user panel.