4-18
Electrical Installation of Converter
RD 500 RD51
DOK-RD500*RD51*******-IB04-EN-P
X2, cable damping L1
RD51.1-x-
Type
number
Execution
022
High current bushing terminal
2
Screw terminal
030
High current bushing terminal
2
Screw terminal
037
High current bushing terminal
2
Screw terminal
045
High current bushing terminal
2
Screw terminal
055
High current bushing terminal
2
Screw terminal
075
High current bushing terminal
2
Screw terminal
090
High current bushing terminal
2
Screw terminal
110
High current bushing terminal
2
Screw terminal
Tab. 4-35
Execution
Identification single connection
Identification signification
C3
D3
Feedback cable damping
Tab. 4-36
Identification single connection
RD51.1-x- Cable cross-
section which can be connected 1),
mm²
AWG
Torque
in Nm
022
0.5 – 10
20 – 8
1.5 – 1.8
030
0.5 – 10
20 – 8
1.5 – 1.8
037
0.5 – 10
20 – 8
1.5 – 1.8
045
0.5 – 10
20 – 8
1.5 – 1.8
055
0.5 – 16
20 – 6
2.0 – 2.3
075
0.5 – 16
20 – 6
2.0 – 2.3
090
0.5 – 16
20 – 6
2.0 – 2.3
110
0.5 – 16
20 – 6
2.0 – 2.3
1):
As a result of the terminal size
Tab. 4-37
Connection cross-section
See table.
Note:
The additional function L1 is required to connect the motor
filter RZM01.1-108 or RZM01.1-130 in converter of power
class 075 and 090.
Execution
Connection cross-section
Torque
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......