4-14
Electrical Installation of Converter
RD 500 RD51
DOK-RD500*RD51*******-IB04-EN-P
X1, DC link
RD51.1-x- Type
Num-
ber
Execution
022
Universal terminal
3
With mounting foot
030
Universal terminal
3
With mounting foot
037
Universal terminal
3
With mounting foot
045
Universal terminal
3
With mounting foot
055
Universal terminal
3
With mounting foot
075
Universal terminal
3
With mounting foot
090
High current bushing terminal
3
Terminal on mounting rail
110
High current bushing terminal
3
Terminal on mounting rail
Tab. 4-25
Execution
Identification single connection
Identification signification
C
DC link connection L+
D
DC link connection L-
F
Accessory: connection of external brake resistor between C
and F
Tab. 4-26
Identification single connection
RD51.1-x- Cable cross-
section which can be connected,
mm²
AWG
Torque
in Nm
022
0.75 – 35
8 - 2
3.2 – 3.7
030
0.75 – 35
8 - 2
3.2 – 3.7
037
0.75 – 35
8 - 2
3.2 – 3.7
045
0.75 – 35
8 - 2
3.2 – 3.7
055
25 – 50
3 – 1/0
6 - 8
075
25 – 50
3 – 1/0
6 - 8
090
35 – 95
2 – 4/0
15 - 20
110
35 – 95
2 – 4/0
15 - 20
Tab. 4-27
Connection cross-section
See table.
Execution
Connection cross-section
Torque
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......