8-26
Parameter Value Assignment
RD 500 RD51
DOK-RD500*RD51*******-IB04-EN-P
Serial communications
Sub-menu to set standard RS485 interfaces.
Para-
meter
No.:
Name
Description / explanation
selectable options
Factory setting
min ... max values
Pass-
word
0499
RS232 baud rate
X11
9600 baud
2
0 = 1200 baud
1 = 2400 baud
2 = 4800 baud
3 = 9600 baud
4 = 19200 baud
5 = 38400 baud
6 = 57600 baud
7 = 76800 baud
0 ... 7
0500
SI1 protocol X12
USS 4 / 6 words
2
The serial interface 1 (SS1) is an RS485 interface
(connection X12).
0 = No protocol
1 = USS 4 / 2 words
2 = USS 4 / 6 words
3 = USS 0 / 2 words
4 = USS 0 / 6 words
5 = USS 4 / 0 words
0 ... 5
0501
SI1 baud rate X12
9600 baud
2
0 = 1200 baud
1 = 2400 baud
2 = 4800 baud
3 = 9600 baud
4 = 19200 baud
5 = 38400 baud
6 = 76800 baud
0 ... 6
0502
SI1 parity X12
Even
2
0 = No parity
1 = ODD
2 = EVEN
0 ... 2
0503
SI1 stop bits X12
1
2
1 or 2 stop bits can be set.
1 ... 2
0504
SI1 slave address
0
2
The drive converter address can be set between 0
and 31 for the RS485 bus.
Caution: There must be no two identical addresses
on the bus
0 ... 31
0505
SI1 Rx watchdog
Fault
2
0 = No reaction
1 = Warning
2 = Fault
0 ... 2
0506
SI1 Rx timeout
0.1 s
2
Timeout (monitoring) time for the standard SS1
interface. If this interface does not receive an error-
free protocol within this time, then the response,
selected in P0505 is initiated.
0.1 ... 60.0 s
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......