Description of Inverter Power Terminals Size Classes A - B
X1, Line supply, DC link connection
RD51.2-xx-
RD51.3-xx-
Type
pole number
Execution
003
Sub-unit
8
Plug on device
005
Sub-unit
8
Plug on device
007
Sub-unit
8
Plug on device
015
Sub-unit
8
Plug on device
018
Sub-unit
8
Plug on device
Tab. 6-1
Execution
Identification single connection
Identification signification
U1
-
V1
-
W1
-
C
C
DC link connection (IC) L+
D
D
DC link connection (IC) L-
F
Tab. 6-2
Identification single connection
Cross section (PE) min 10 mm² (AWG 6)
steel plate lug on the housing with captive nut M5 (torque 2.5 – 3.0 Nm)
RD51.2-xx-
RD51.3-xx-
Cable cross-
section which can be connected 1), mm²
AWG
003
0.5 - 6
20 - 10
005
0.5 - 6
20 - 10
007
0.5 - 6
20 - 10
015
0.5 - 6
20 - 10
018
0.5 - 6
20 - 10
1):
As a result of the terminal size
Tab. 6-3
Connection cross-section
1.2 – 1.5 Nm
Execution
Protective conductor connection
Connection cross-section
Torque