![REXROTH RD 500 Series Applications Manual Download Page 142](http://html1.mh-extra.com/html/rexroth/rd-500-series/rd-500-series_applications-manual_1449588142.webp)
5-2
Inverter Technical Data
RD 500 RD51
DOK-RD500*RD51*******-IB04-EN-P
5.2
Technical Data for Size Classes A and B with Pulse
Frequency f
p
= 12 kHz
12 kHz
RD51.2
003
005
007
015
018
Supply voltage DC 530 ... 670 V (± 20 %)
1)
Output frequency Hz
0 - 1400
Rated current
A 4
7
10
18
22
Peak current for t = 60 s A
5.2
9.1
13
23
29
t = 1 s A
6.8
12
17
31
37
t = 0.5 s A
8
14
20
36
44
Rated output S
N
kVA 2.6
4.6
6.6
12
14
Peak power for t = 60 s kVA 3.4
6.0
8.6
16
18
Ambient conditions, noise suppression level, interference immunity
Environmental class
3K3 according to DIN IEC 721-3-3 (ambient temperature 0 – 40 °C operation,
to 50 °C power reduction at 2.5 % per K)
Cooling air requirement
m³ / s
0.03
0.03
0.03
0.05
0.05
Power loss kW 0.16
0.23
0.27
0.43
0.50
Radio int. sup. level / noise immunity
A 1 according to EN 55011 / EN 61800-3
Mechanical design
Size classes
A
A
A
B
B
Degree of protection
IP 20 according to EN 60529, with connected plug
Weight of inverter for the various cooling types
D Plug-through cooler
kg
5.5
5.5
5.5
10.3
10.3
L Forced air cooling
kg
6.5
6.5
6.5
11.3
11.3
P heat dissipation panel
kg
5.5
5.5
5.5
10.3
10.3
1:
Starting at an output voltage Ua >400 V, the rated current is linearly
reduced from 100 % to 83 % for Va = 480 V.
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......