![REXROTH RD 500 Series Applications Manual Download Page 194](http://html1.mh-extra.com/html/rexroth/rd-500-series/rd-500-series_applications-manual_1449588194.webp)
6-20
Electrical Installation of Inverter
RD 500 RD51
DOK-RD500*RD51*******-IB04-EN-P
X83, 24 V Stand-by power supply for the electronics
(only in A1 and A2)
RD51.1-xx-
RD51.3-xx-
Type
pole number
Execution
022
plug
2
Plug on device
030
plug
2
Plug on device
037
plug
2
Plug on device
045
plug
2
Plug on device
055
plug
2
Plug on device
075
plug
2
Plug on device
090
plug
2
Plug on device
110
plug
2
Plug on device
Tab. 6-43
Execution
Identification single connection
Identification signification
1
P24 V 24 V DC –15 / +20 %, ripple, max 5 % (VDE0411 / 500),
power consumption ~40 W, startup current 5 A
2
ground
Tab. 6-44
Identification single connection
RD51.1-xx-
RD51.3-xx-
Recommended
minimum cross-
section mm²
AWG
Cable cross-
section which can
be connected, mm²
AWG
022
1.5
16
0.2 – 2.5
24 - 14
030
1.5
16
0.2 – 2.5
24 - 14
037
1.5
16
0.2 – 2.5
24 - 14
045
1.5
16
0.2 – 2.5
24 - 14
055
1.5
16
0.2 – 2.5
24 - 14
075
1.5
16
0.2 – 2.5
24 - 14
090
1.5
16
0.2 – 2.5
24 - 14
110
1.5
16
0.2 – 2.5
24 - 14
Tab. 6-45
Connection cross-section
0.22 – 0.25 Nm
Execution
Connection cross-section
Torque
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......