![REXROTH RD 500 Series Applications Manual Download Page 199](http://html1.mh-extra.com/html/rexroth/rd-500-series/rd-500-series_applications-manual_1449588199.webp)
RD 500 RD51
Electrical Installation of Inverter
6-25
DOK-RD500*RD51*******-IB04-EN-P
Fuses inverter Size class G
RD51.1-xx-
Maximum series fuse, type gL, A 1)
132
250
160
315
200
400
1):
Safety values are provided for the DC 560 V input voltage and for
the rated output X1 of the device. If the input voltage differs, the
safety value must be changed.
Tab. 6-18:
series fuses
Fuses motor inverter SFT- Operation Size class G
RD51.3-xx-
Maximum series fuse Type gL at 750 V in A
1)
160
315
1):
or AC-fuses with min. 750 V at L / R = 20 ms.
Tab. 6-19:
series fuses
X2, Motor connection
RD51.1-xx-
RD51.3-xx-
Type
number
Execution
132
High current terminal 3
Terminal on mounting rail
160
High current terminal 3
Terminal on mounting rail
200
High current terminal 3
Terminal on mounting rail
Tab. 6-20:
Execution
Identification single connection
Identification
signification
U2
Motor connection U
V2
Motor connection V
W2
Motor connection W
Tab. 6-21:
Identification single connection
•
Stud M8 (torque 12.0 Nm)
RD51.1-xx-
RD51.3-xx-
Cable cross-section which can be
connected 1) mm²
AWG
132
50 - 150
1/0 – 6/0
160
50 - 150
1/0 – 6/0
200
70 - 240
2/0 – 500MCM
1):
As a result of the terminal size
Tab. 6-22:
Connection cross-section
25 – 30 Nm.
fuses
fuses
Execution
Protective conductor connection
Connection cross-section
torque
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......