3152B User Manual
Publication No. 980935 Rev. A
5-24 Programming Reference
EADS North America Test and Services
Table 5-3, Instrument & Output Control Commands Summary (Continued)
Keyword
Parameter Form
Default
3152A
HS
[:SOURce]
:ROSCillator
:SOURce
INTernal | EXTernal | CLK10
INT
0028A
:FREQuency
:EXTernal?
9
0420@?
[:CW]
10e-3 to 100e6 | MINimum | MAXimum
1e6
9
0400A
:RASTer
10e-6 to 250e6 | MINimum | MAXimum
1e6
9
0410A
:SOURce
INTernal | EXTernal | ECLTrg0 | LBUS
INT
0411A
:VOLTage
[:LEVel]
[:AMPLitude]
10e-3 to 16 | MINimum | MAXimum
5
9
0500A
:OFFSet
-7.992
to
7.992
0
9
0501A
:PHASe
[:OFFSet]
0 to 1e6-1 (0 to 2/4e6-1 with option 1/2)
0
0027A
:FUNCtion
:MODE
FIXed | USER | SEQuence | SWEep (calculated)(*) |
MODulation | DPULse | HALFcycle | COUNter
FIX
0610A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com