VTrak M610p Product Manual
226
Battery capacity is normal Normal.
Battery is discharging
Battery is undergoing reconditioning.
Battery is charging
Battery is being recharged.
Battery reconditioning is
complete
Battery reconditioning is finished.
Battery is malfunctioning
Run battery reconditioning. See page 85 or
page 128. If this message reappears, replace the
battery.
Battery reconditioned
successfully
Battery reconditioning is finished.
Battery reconditioning has
failed
Replace the battery. See page 184.
Battery is reaching end of
life
Replace the battery. See page 184.
Battery is removed
The battery was disconnected or removed. Reinstall
the battery. See page 184.
Battery charging failed
Replace the battery. See page 184.
Battery reconditioning
started
Battery reconditioning has begun.
Battery recondition
terminated
The battery was disconnected or removed during
reconditioning. Reinstall the battery. See page 184.
Blowers
Blowers have started
Normal.
Blowers have stopped
Verify that the cooling unit is properly installed. If the
blower still does not turn, replace the blowers. See
page 181.
Blower speed is
increased
Check the VTrak for overheating. See page 245.
Blower speed is
decreased
Temporary overheat condition was corrected.
Blowers are NOT
functioning
Replace the blowers. See page 181.
Blowers have been
inserted
Normal.
Reported Event
Corrective Action
Summary of Contents for VTRAK M610p
Page 1: ...VTRAK M610p Product Manual Version 1 0 ...
Page 30: ...VTrak M610p Product Manual 18 ...
Page 44: ...VTrak M610p Product Manual 32 ...
Page 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Page 128: ...VTrak M610p Product Manual 116 ...
Page 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Page 274: ...VTrak M610p Product Manual 262 ...