VTrak M610p Product Manual
240
After the disk array rebuilds itself using the spare drive, you must replace the
failed drive.
To set up a spare drive, see “Creating a Spare Drive” on page 112 (WebPAM
PROe) or page 154 (CLU).
Without a Hot Spare Drive
If there is no hot spare drive of adequate capacity, you must remove the failed
drive and install an unconfigured replacement drive of the same or greater
capacity in the same slot as the failed drive. Until you install the replacement
drive, the logical drive will remain Degraded.
•
If the Auto Rebuild function is ENABLED, the disk array will begin to rebuild
automatically as soon as you replace the failed drive.
•
If the Auto Rebuild function is DISABLED, you must manually rebuild the
disk array after you replace the failed drive.
To enable Automatic Rebuild, see “Making Background Activity Settings” on
page 47 (WebPAM PROe) or page 150 (CLU).
To set Hot Spare Policy, see “Making Spare Drive Settings” on page 113
(WebPAM PROe) or page 155 (CLU)
.
Rebuild Operation
During rebuild:
•
The alarm sounds a single short beep, repeated
•
No warning icon displays over the Disk Array or Logical Drive in the Tree.
Management View reports the Disk Array’s Operational Status as OK,
Rebuilding.
•
The drive carrier holding the rebuilding physical drive displays a green
Activity (lower) LED while the Status (upper) LED flashes green once per
second.
Important
If your replacement disk drive was formerly part of a different disk
array or logical drive, you must clear the configuration data on the
replacement drive before you use it.
See “Clearing Stale and PFA Conditions” on page 89 (WebPAM
PROe) or page 131 (CLU).
Summary of Contents for VTRAK M610p
Page 1: ...VTRAK M610p Product Manual Version 1 0 ...
Page 30: ...VTrak M610p Product Manual 18 ...
Page 44: ...VTrak M610p Product Manual 32 ...
Page 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Page 128: ...VTrak M610p Product Manual 116 ...
Page 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Page 274: ...VTrak M610p Product Manual 262 ...