Chapter 5: Management with the CLU
171
Shutting Down the Subsystem
There are two methods for shutting down the subsystem. Choose one of the
following procedures:
•
Shutting down the VTrak – Telnet Connection (page 171)
•
Shutting down the VTrak – Serial Connection (page 171)
Shutting down the VTrak – Telnet Connection
This function enables you to shutdown the VTrak subsystem on a Telnet
connection. You can only do part of this procedure in the CLU. Additional action
is required, as described below. To shutdown the VTrak:
1.
From the Main Menu, highlight
Additional Info and Management
and press
Enter.
2.
Highlight
Shutdown or Restart
and press Enter.
3.
Highlight
Shutdown or Restart
and press Enter.
4.
Highlight
Option
and press the spacebar to display
Restart
.
5.
Highlight
Submit
and press Enter.
A warning message appears.
6.
Press Y to continue.
The screen will go blank.
7.
Wait for no less than two minutes.
8.
Manually turn off the power supply switches on the back of the subsystem.
Shutting down the VTrak – Serial Connection
This function enables you to shutdown the VTrak subsystem on a serial
connection. You can only do part of this procedure in the CLU. Additional action
is required, as described below. To shutdown the VTrak:
1.
From the Main Menu, highlight
Additional Info and Management
and press
Enter.
2.
Highlight
Shutdown or Restart
and press Enter.
3.
Highlight
Shutdown or Restart
and press Enter.
4.
Highlight
Option
and press the spacebar to display
Restart
.
5.
Highlight
Submit
and press Enter.
A warning message appears.
6.
Press Y to continue.
7.
Turn off the power supply switches when you see the following message:
Summary of Contents for VTRAK M610p
Page 1: ...VTRAK M610p Product Manual Version 1 0 ...
Page 30: ...VTrak M610p Product Manual 18 ...
Page 44: ...VTrak M610p Product Manual 32 ...
Page 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Page 128: ...VTrak M610p Product Manual 116 ...
Page 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Page 274: ...VTrak M610p Product Manual 262 ...