Chapter 5: Management with the CLU
145
3.
To set write cache policy for this disk array, highlight
WritePolicy
and press
the spacebar to toggle between
WriteBack
and
WriteThru
(write though).
4.
Press Ctrl-A to save your settings.
Setting Read Cache Policy
To set read cache policy on a logical drive:
1.
From the Main Menu, highlight
Logical Drive Management
and press Enter.
2.
Highlight the logical drive you want and press Enter.
3.
To set read cache policy for this disk array, highlight
ReadPolicy
and press
the spacebar to toggle though
ReadCache
,
ReadAhead
and
None
.
4.
Press Ctrl-A to save your settings.
Initializing a Logical Drive
This function sets all data bits in the logical drive to zero.
To initialize a logical drive:
1.
From the Main Menu, highlight
Logical Drive Management
and press Enter.
2.
Highlight the logical drive you want and press Enter.
3.
Highlight
Background Activity
and press Enter.
4.
Highlight
Start Initialization
and press Enter.
The initialization parameters appear.
•
Initialization pattern. The default 00000000 is best for most applications
•
Quick Initialization – Yes means only the disk data format of the logical
drives are initialized.
•
Quick Initialization Rate – Enter a value or use the default 64 bits.
To change a parameter, highlight it and press the backspace key to erase
the current value, then type the new value.
5.
Highlight
Start
and press Enter.
If necessary, you can pause and resume or stop and restart the Initialization.
You cannot access the logical drive until Initialization has finished.
Caution
When you initialize a logical drive, you delete all the data it
contains. Back up all important data before initializing a logical
drive.
Summary of Contents for VTRAK M610p
Page 1: ...VTRAK M610p Product Manual Version 1 0 ...
Page 30: ...VTrak M610p Product Manual 18 ...
Page 44: ...VTrak M610p Product Manual 32 ...
Page 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Page 128: ...VTrak M610p Product Manual 116 ...
Page 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Page 274: ...VTrak M610p Product Manual 262 ...