VTrak M610p Product Manual
140
3.
Highlight
Transport
and press Enter.
4.
Press Y to confirm.
Rebuilding a Disk Array
Before you can rebuild, you must have a replacement physical drive of adequate
capacity or your disk array. To rebuild a disk array:
1.
From the Main Menu, highlight
Disk Array Management
and press Enter.
2.
Highlight the disk array you want and press Enter.
3.
Highlight
Background Activities
and press Enter.
4.
Highlight
Rebuild
and press Enter.
5.
Specify the source and target physical drives.
6.
Highlight
Start
and press Enter.
Migrating a Disk Array
In order to migrate RAID level, you may have to add physical drives. For more
information, see “RAID Level Migration” on page 205.
To migrate a disk array:
1.
From the Main Menu, highlight
Disk Array Management
and press Enter.
2.
Highlight the disk array you want and press Enter.
3.
Highlight
Background Activities
and press Enter.
4.
Highlight
Migration
and press Enter.
5.
Highlight the physical drive you want to add and press the spacebar to select
it.
Repeat this action to add more physical drives.
6.
Highlight
Save Settings and Continue
and press Enter.
7.
To change RAID level, Highlight the logical drive in the list and press Enter.
8.
Highlight
RAID Level
and press the spacebar to toggle through the available
RAID levels.
9.
Optional. If you want to increase capacity, highlight
Expand Capacity
and
press the spacebar to toggle to
Yes
.
Notes
•
You can add physical drives to a RAID 50 array but you
cannot change the number of axles.
•
If you add an odd number of physical drives to a RAID 10
array, it will become a RAID 1E array by default.
Summary of Contents for VTRAK M610p
Page 1: ...VTRAK M610p Product Manual Version 1 0 ...
Page 30: ...VTrak M610p Product Manual 18 ...
Page 44: ...VTrak M610p Product Manual 32 ...
Page 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Page 128: ...VTrak M610p Product Manual 116 ...
Page 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...
Page 274: ...VTrak M610p Product Manual 262 ...