Chapter 6: Maintenance
181
Replacing a Cooling Unit Fan
The fan in each cooling unit is replaced as an individual part. No tools are
required for this procedure.
Remove and Replace a Fan
To replace a fan:
1.
Verify that the Fan LED is amber or red.
Figure 2. Fan LED
2.
Press the release button and pull the handle downward. See Figure 3.
3.
Pull the cooling unit out of the VTrak enclosure.
Figure 3. Removing a cooling unit from the enclosure
4.
Loosen the thumbscrew. A retainer keeps the thumbscrew in place.
5.
Grasp the top section near the thumbscrews and lift it off the bottom section.
Separate the cooling unit section to access the blower. See Figure 4.
Fan LED
Summary of Contents for VTRAK M610p
Page 1: ...VTRAK M610p Product Manual Version 1 0 ...
Page 30: ...VTrak M610p Product Manual 18 ...
Page 44: ...VTrak M610p Product Manual 32 ...
Page 47: ...Chapter 4 Management with WebPAM PROe 35 Figure 1 The WebPAM PROe log in screen ...
Page 128: ...VTrak M610p Product Manual 116 ...
Page 184: ...VTrak M610p Product Manual 172 Shutdown complete It is now safe to power off the subsystem ...