Chapter 5: Management with the CLU
129
5.
Highlight
Recondition Battery
and press Enter.
6.
Press Y to confirm.
During reconditioning, Battery status can show “discharging” and
“recharging”, and a value will display next to Current. During that time, the
controller cache is reset to Write Thru. Reconditioning runs in the
background and stops automatically upon completion.
VTrak automatically reconditions the battery every two months.
Locating an Enclosure
This feature helps you identify the physical VTrak enclosure you are working with
through the CLU.
1.
From the Main Menu, highlight
Subsystem Management
and press Enter.
2.
Highlight
Enclosure Management
and press Enter.
3.
Highlight
Locate Enclosure
and press Enter.
The LEDs on the front of the VTrak will blink for one minute.